WSL51, 64, WSL76, WSL92, WSL150 – Wall Lipped Studs
MAXIMUM WALL HEIGHTS
- Stud Walls lined both sides with plasterboard
- Lateral Pressure : 0.25 kPa permissible
- Internal wind pressure 0.375 kPa (Ultimate)
Stud Size mm (Lipped Stud) | Thickness BMT mm | Plaster Board | Plaster Board | Stud Spacing in mm |
Thickness | Type | 600 | 450 | 300 |
mm | | Maximum Wall Height in MM |
|
WSL51 | 0.50 | 10 | Both Sides | 2810 | 3025 | 3305 |
13 | Both Sides | 3210 | 3410 | 3635 |
16 | Both Sides | 3350 | 3540 | 3810 |
|
WSL64 | 0.50 | 13 | Both Sides | 3645 | 4135 | 4445 |
0.75 |
13 | Both Sides | 4250 | 4435 | 4765 |
1.15 |
13 | Both Sides | 4535 | 4780 | 5205 |
|
WSL76 | 0.55 | 13 | Both Sides | 4175 | 4745 | 5065 |
0.75 |
13 | Both Sides | 4755 | 4970 | 5360 |
1.15 |
13 | Both Sides | 5085 | 5375 | 5875 |
|
WSL92 | 0.55 | 13 | Both Sides | 5055 | 5390 | 5775 |
0.75 |
13 | Both Sides | 5400 | 5660 | 6125 |
1.15 |
13 | Both Sides | 5805 | 6145 | 6740 |
|
WSL150 |
0.75 |
13 | Both Sides | 7230 | 7695 | 8480 |
1.15 |
13 | Both Sides | 7930 | 8510 | 9480 |
Based on:
- Deflection = H/240.
- Heights are as per AS1538.
- Noggins Tracks:
- 0000 - 3000mm height = One row of Noggin Track required.
- 3000 - 6000mm height = Two rows of Noggin Track required.
- 6000 - 8300mm height = Three rows of Noggin Track required.
- Stud Walls as per AS4600 & AS1538- cold formed steel structures code.
- G300 steel
|
|