Home » General / Design Information  

Steel Wall Systems Manual

General information/ Warranty and design considerations
Engineering design certification
Certification, standards and testing
Performance
Technical services
Fire and acoustic rated systems

Peer Steel Wall Products
Partition or wall studs and track
Deflection head and noggin track
Accessories for acoustic applications
Top hats
Plaster accessories

Partition and wall framing – installation
Bottom track fixing detail
Top (Head) track fixing detail
Top (Head) track fixing detail – suspended ceiling
Deflection head track fixing detail
Fixing methods explained
Plasterboard installation
Control joints explained
Storage and Handling
Table SWS-01 - Wall Lipped Studs
Table SWS-02 - Wall Lipped Studs
Table SWS-03 - Top Hats
Table SWS-04 - Top Hats
Design notes and sectional properties
WSL design examples
Top Hat design examples
Sectional properties SWS-05
Sectional properties SWS-06
Sectional properties SWS-07
Sectional properties SWS-08
Sectional properties SWS-09
Sectional properties SWS-10
Sectional properties SWS-11
Sectional properties SWS-12
Sectional properties SWS-13
Sectional properties SWS-14
Sectional properties SWS-15

Peer Facade System Manual

General / Design & Warranty Information
Engineering design certification
Certification, standards and testing
Performance
Technical services

Peer Façade system Products
Façade system Backing Strip
Top Hat 50, 120 and EPDM foam seal
Façade EPDM seal characteristics
Panel Layout and Top Hat spacing
Top Hat levelling and fixing – EPDM Foam seal application
Pre mark and drill boards prior to fixing
Backing Strip as a vertical spacer and sealant application
Insertion of backing strip and overlapping seal details
Backing strip overlapping seal and prep for Top board
Fixing to layer of boards and prep screw holes for filling
Finish façade joint sealing & Control Joints
Control Joints
Storage, Handling & Design Capacities
Section properties TH120
Section properties TH75 & TH50
Span table maximum wind pressure

Concealed Ceiling systems Manual

General / Design & Warranty Information
Engineering design certification
Technical services
Certification, standards and testing
Performance

PEER Concealed Ceiling Steel
Product Breakdown
Furring channel
Top cross rail
Clips
Miscellaneous components
Acoustic application accessories
Top hats
Ceiling battens
Ceiling joists
Concealed ceiling systems install
Typical suspended ceiling with TCR/FC
Direct fixing of furring channels
Drop ceiling/ceiling bulkhead
Fire rated ceilings
Acoustic STC rated ceilings
Typical concealed ceiling joists
Curven and raked ceilings
Plasterboard installation
Expansions and control joints

Design notes
Span table CCS01
Span table CCS02
Span table CCS03
Span table CCS04
Span table CCS05
Span table CCS06
Span table CCS07
Clip Capacity Table CCS08
Sectional properties SP-01
Sectional properties SP-02
Sectional properties SP-03
Sectional properties SP-04
Sectional properties SP-05

Exposed Grid system Manual

General / Design & Warranty Information
Engineering design certification
Certification, standards and testing
Technical services

PEER Exposed Grid Ceiling
Simplicitee components
Simplicitee components details
Two way exposed grid
One way linear grid
Raked ceiling detail
Light fitting detail

Installation details
Two way exposed grid
Part tile lengths/widths
Wall angle trim fixing
Suspension rod fixing
Main/Cross runner suspension clips
Main runner to wall angle junction
Detail at light fitting
Main runner to wall angle junction
Maximum load Table EGS01
Clip Capacity Table EGS-02
Grid layout examples
Ceiling tiles
Sectional properties SP-01

 « Back to Website.

Previous Page
Storage, Handling & Design Capacities
Next Page

Storage and Handling of product on Site

  • Products manufactured by Peer Industries are produced from coated steel coil material which is classified as non hazardous material.
  • Products are supplied in varied pack and sub pack quantities and should be handled in accordance with the recommendations contained in AS 1470
  • Storage of metal products should be in accordance with Peer Industries recommendations as listed below.
  • Top Hats, backing strips and expanded foam EPDM seal should be stored in dry areas free from dirt, oil and airborne contaminants such as acids and salt sprays.
  • Where possible all material used in the construction of facade walls should be delivered to site prior to installation and handled in a manner that reduces the risk of damage.
  • All material should be kept dry in an area where accidental damage cannot occur.
  • All framing should be sheeted as soon as possible after installation to protect the coating
  • Steel products should be used as soon as possible after delivery.

Peer Façade System design capacities

The design capacities of Peer Façade System are in Limit state format and are based on AS1170.2 – 2002 – Wind Loads.

The top hat capacities in table have been calculated in accordance with
AS4600- cold formed steel structures. The deflection of the Top hats is based on serviceability factor of 0.6 x ultimate wind loads and is limited to Span /240.

The peer façade system can be used for cyclonic wind areas – region C & D based on wind pressures.

It is the responsibility of the Project Engineer to specify the connection of top hats to the support structure. Minimum 12g screw on each leg of top hat i.e. two 12g screws at each crossing of top hat & purlin.

   PEER Industries Technical Manual Rev 05