Home » General / Design Information » Certification, standards and testing  

Steel Wall Systems Manual

General information/ Warranty and design considerations
Engineering design certification
Certification, standards and testing
Performance
Technical services
Fire and acoustic rated systems

Peer Steel Wall Products
Partition or wall studs and track
Deflection head and noggin track
Accessories for acoustic applications
Top hats
Plaster accessories

Partition and wall framing – installation
Bottom track fixing detail
Top (Head) track fixing detail
Top (Head) track fixing detail – suspended ceiling
Deflection head track fixing detail
Fixing methods explained
Plasterboard installation
Control joints explained
Storage and Handling
Table SWS-01 - Wall Lipped Studs
Table SWS-02 - Wall Lipped Studs
Table SWS-03 - Top Hats
Table SWS-04 - Top Hats
Design notes and sectional properties
WSL design examples
Top Hat design examples
Sectional properties SWS-05
Sectional properties SWS-06
Sectional properties SWS-07
Sectional properties SWS-08
Sectional properties SWS-09
Sectional properties SWS-10
Sectional properties SWS-11
Sectional properties SWS-12
Sectional properties SWS-13
Sectional properties SWS-14
Sectional properties SWS-15

Peer Facade System Manual

General / Design & Warranty Information
Engineering design certification
Certification, standards and testing
Performance
Technical services

Peer Façade system Products
Façade system Backing Strip
Top Hat 50, 120 and EPDM foam seal
Façade EPDM seal characteristics
Panel Layout and Top Hat spacing
Top Hat levelling and fixing – EPDM Foam seal application
Pre mark and drill boards prior to fixing
Backing Strip as a vertical spacer and sealant application
Insertion of backing strip and overlapping seal details
Backing strip overlapping seal and prep for Top board
Fixing to layer of boards and prep screw holes for filling
Finish façade joint sealing & Control Joints
Control Joints
Storage, Handling & Design Capacities
Section properties TH120
Section properties TH75 & TH50
Span table maximum wind pressure

Concealed Ceiling systems Manual

General / Design & Warranty Information
Engineering design certification
Technical services
Certification, standards and testing
Performance

PEER Concealed Ceiling Steel
Product Breakdown
Furring channel
Top cross rail
Clips
Miscellaneous components
Acoustic application accessories
Top hats
Ceiling battens
Ceiling joists
Concealed ceiling systems install
Typical suspended ceiling with TCR/FC
Direct fixing of furring channels
Drop ceiling/ceiling bulkhead
Fire rated ceilings
Acoustic STC rated ceilings
Typical concealed ceiling joists
Curven and raked ceilings
Plasterboard installation
Expansions and control joints

Design notes
Span table CCS01
Span table CCS02
Span table CCS03
Span table CCS04
Span table CCS05
Span table CCS06
Span table CCS07
Clip Capacity Table CCS08
Sectional properties SP-01
Sectional properties SP-02
Sectional properties SP-03
Sectional properties SP-04
Sectional properties SP-05

Exposed Grid system Manual

General / Design & Warranty Information
Engineering design certification
Certification, standards and testing
Technical services

PEER Exposed Grid Ceiling
Simplicitee components
Simplicitee components details
Two way exposed grid
One way linear grid
Raked ceiling detail
Light fitting detail

Installation details
Two way exposed grid
Part tile lengths/widths
Wall angle trim fixing
Suspension rod fixing
Main/Cross runner suspension clips
Main runner to wall angle junction
Detail at light fitting
Main runner to wall angle junction
Maximum load Table EGS01
Clip Capacity Table EGS-02
Grid layout examples
Ceiling tiles
Sectional properties SP-01
Previous Page
Certification, standards and testing
Next Page

Testing and Standards

Australian and New Zealand Standards

AS 1397 - 2001 Steel Sheet and Strip Hot Dipped Zinc-coated or Aluminium/Zinc coated
AS/NZS 4600-1996 & AS 1538 – 1988 SAA Cold Formed Steel Structures.
AS4100 Steel Structure Code.
AS3566 Screws - self-drilling - for the building and Construction industry.
AS4055 –1992 Wind Loads for Housing.
AS1170 – 0, 1, & 2 – 2002/1989 Dead, Live and Wind Loads.
AS4284-1995 Testing of Building Facades.

Tests

Peer Industries Pty Ltd cold-formed steel Top Hats are tested in conjunction with Cement Fibre Sheeting conforming to AS4284 - 1995 for:

   (a) Preliminary test.
   (b) Structural test.
   (c) Air filtration test.
   (d) Water penetration test including both static and cyclic pressure.
   (e) Proof test.

CSIRO Test Report – DTF 817

Peer Industries cold-formed steel Top hats are tested in conjunction with compressed fibre cement sheeting sources from a variety of sources

Material:

Peer Industries cold roll formed steel sections and pressed products are manufactured from Zinc coated steel strip conforming to AS 1397 for thickness up to and including 1.55mm BMT (base metal thickness).
The steel strip for the various section sizes has a minimum yield stress of 300 Mpa.

Coating:

All Peer Industries cold roll formed steel sections are coated with zinc with a minimum coating mass of 220 - 275 grams/m2 as indicated.

Performance

Peer cold roll formed steel sections and pressed products will perform as specified if used in accordance with the recommendations and details set down in this technical brochure and related design references together with good trade practices.
Any variations from these recommendations and details will require special design and detailing.
Information in this brochure is current at the time of printing.
Specifications and recommendations are subject to change without notice.
Whilst every care is taken at the time of the preparation of this Brochure, Peer accepts no liability for any errors or ambiguities.
Contact any Peer office to discuss any such concerns.
For applications outside the scope of this design manual, contact Peer design on design@01Peer.comor contact our nearest office by calling 1300 725 675 from anywhere in Australia.

   PEER Industries Technical Manual Rev 05