Peer clip capacity based on testing by ETRS – Report No. 4206-2014/1 –
21/12/2006. & 4206-2014/3 – 05/04/2007 and 4206-2014/4-08/06/2007
These capacities are maximum allowable as per AS2785 – 2000 and 1985
Limit state design capacity is for AS2785 – 2000 – Suspended Ceilings Design
and Installation
Working load is for AS2785 – 1985 – Suspended Ceilings Design & Installation.
Part number |
Limit Sate design capacity
In kN
|
Working load
Weight on boards on clip
In Kgs
|
| C001 |
1.45 |
82 |
| C001-DCS |
3.13 |
177 |
| C001-SUS |
0.94 |
53 |
| C26-80 |
0.85 |
48 |
| C26-180 |
0.85 |
48 |
| C37-7H |
1.20 |
68 |
| C37-M6 |
1.17 |
66 |
| C39 |
0.94 |
53 |
| C42 |
1.02 |
58 |
| C47-74 |
1.75 |
99 |
| C74 |
0.93 |
52 |
| C52 |
0.90 |
51 |
| C54 |
1.68 |
95 |
| C60 |
1.64 |
92 |
| C60DF |
1.64 |
92 |
| C60LDF |
1.64 |
92 |
| C61S Constrained |
1.13 |
64 |
| C61S Not Constrained |
0.81 |
46 |
| C79S |
0.95 |
54 |
| C85 |
0.53 |
30 |
| C409 |
1.20 |
68 |
| CDB26-80 |
0.57 |
32 |
| CDB26-150 |
0.57 |
32 |
| CBET.FIX First tooth |
0.29 |
16 |
| CBET.FIX Last tooth |
0.67 |
37 |
| CFCAM First tooth |
0.57 |
32 |
| CFCRESAM First tooth |
0.52 |
29 |
| CFCRESAM Last tooth |
0.62 |
34 |
| CFCSAM |
1.59 |
89 |
| CTCR-100 |
1.13 |
63 |
| CTCRRES-100 Last tooth |
1.32 |
74 |
| C24 Suspended |
1.31 |
74 |
| C24 Hard bolted |
1.34 |
75 |
| C66 |
1.40 |
79 |
| C001 |
1.25 |
70 |
NOTE:
Limit state capacity less than 0.50 kN or Working load less than 25 kgs – do not use that clip at that
particular location.
(Refer to Shaded area – CBET-FIX – do not use the first tooth of the clip to support furring channel)
|