(3) Drop Ceiling/Ceiling Bulkhead
Drop ceilings are required to allow for ducting, mechanical and electrical services, or as a feature with maximum of 600 mm drop
- Locate the position of the drop ceiling and mark the position of suspension rod
Brackets (Peer product code C74 or C47-74) as per detail on trusses, purlins or concrete based on the ceiling plan.
- Join top cross rails TCR25 or TCR38 to suit site situation as per detail.
- Alternatively join furring channel FC18 or FC28 to suit site situation as per detail.
- Install suspension rod brackets C74 or C47-74, suspension rods C21, top cross rails TCR25
or TCR38 and furring channels FC18 or FC28 as per typical suspended concealed ceiling
system.
- Check and adjust drop ceiling and concealed ceiling system using a laser or other suitable
levelling device.
-
Install ceiling lining board as per manufacturers specification
|