Exposed Grid Ceiling Main and Cross runners
Peer Part No |
Product
Description |
Thickness
t |
Yield
Strength |
Centroid |
Area |
Second
Moment
Of
Area |
|
|
mm BMT |
FY MPa |
YC mm |
A mm2 |
IX-X x 103 mm4 |
IY-Y x 103 mm4 |
XGSMR38-36 |
Main Runner |
0.33 |
300 |
15.29 |
33.46 |
5.2 |
0.37 |
XGSCR38-12 |
Cross Runner 38mm |
0.33 |
300 |
15.29 |
33.46 |
5.2 |
0.37 |
XGSCR32-12 |
Cross Runner 32mm |
0.33 |
300 |
12.27 |
28.90 |
3.29 |
0.34 |
Peer Part No. |
|
Section
Modulus |
Radius
Of
Gyration |
|
|
ZX-X mm3 |
ZY-Y mm3 |
Rx |
Ry |
mm |
mm |
XGSMR38-36 |
Main Runner |
232 |
30.40 |
12.50 |
3.31 |
XGSCR38-12 |
Cross Runner 38mm |
232 |
30.40 |
12.50 |
3.31 |
XGSCR32-12 |
Cross Runner 32mm |
169 |
28.50 |
10.70 |
3.45 |
Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code Material Specifications
- Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397.
- Material : G2 Z180, Yield Strength - Fy = 300 Mpa and coating grade Z180 (180g/m2 zinc)
|