FCCB 22mm Ceiling Batten
Peer Part No |
Depth |
Width |
Thickness |
Shear
Centre |
Centroid |
Yield Strength |
Area |
Mono
symmetry Section Constant |
|
D
mm |
B
mm |
t
mm
BMT |
YS
mm |
XC
mm |
YC
mm |
FY
MPa |
A
mm2 |
ßx
mm |
FCCB22 |
21.0 |
30 |
0.48 |
6.75 |
33.0 |
10.66 |
550 |
49.9 |
59.6 |
Peer Part No |
Torsion
Constant |
Second Moment
of Area |
Section
Modulus |
Radius
of
Gyration |
Form
Factor |
Warping Constant |
|
J
mm4 |
IX-X
x 103 mm4 |
IY-Y
x 103 mm4 |
ZX-X
mm3 |
ZY-Y
mm3 |
Rx
mm |
Ry
mm |
Q |
Iw
x 106 mm4 |
FCCB22 |
3.83 |
3.62 |
20.12 |
339 |
610 |
8.51 |
20.1 |
0.892 |
0.71 |
Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specifications
- Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397.
- Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade – AZ150 g/m2 zinc/alum.
|